StoTherm NExT® Continuous Insulation

Pre-assembled Collections CLICK ON THE LISTING BELOW TO DOWNLOAD FILES Back To Top

CAD
3D
Specs
About
Media
Education
PrintCAD
Close
1
(10.00) System Components
Close
2
(10.10A) Termination at Grade: Sheathing Flush with Foundation
Close
3
(10.10B) Termination at Grade: Sheathing overlaps Foundation
Close
4
(10.10C) Termination at Grade: Concealed Starter Track
Close
5
(10.11) Termination at Protected Sidewalk
Close
6
(10.14) Termination at Grade: Concealed Starter Track
Close
7
(10.15) Termination with Uni-Track Noncombustible Construction
Close
8
(10.16) Termination with Uni-Track: Combustible Construction
Close
9
(10.23A) Preparation of Rough Opening
Close
10
(10.23B) Installation of Window Head Flashing
Close
11
(10.23C) Installation of Sill Flashing Beneath Sill Feature
Close
12
(10.24A) Commercial Window Head (seal & backer rod)
Close
13
(10.24B) Commercial Window Head (fillet seal)
Close
14
(10.25A) Commercial Window Jamb (seal & backer rod)
Close
15
(10.25B) Commercial Window Jamb (fillet seal)
Close
16
(10.26A) Commercial Window Sill (seal & backer rod)
Close
17
(10.26B) Commercial Window Sill (fillet seal)
Close
18
(10.27) Flanged Window Head
Close
19
(10.28) Flanged Window Jamb
Close
20
(10.29) Flanged Window Sill
Close
21
(10.29A) Flanged Window Sill: Concealed Flashing
Close
22
(10.30) Unvented Insulated Soffit
Close
23
(10.31) Vented Insulated Soffit
Close
24
(10.33) Unvented Insulated Soffit (without starter track)
Close
25
(10.40) Floor Line without Joint
Close
26
(10.41) Floor Line with Joint (Starter Track)
Close
27
(10.41B) Floor Line with Joint: Noncombustible Construction
Close
28
(10.41C) Floor Line with Joint: Nocombustible Construction
Close
29
(10.42) Horizontal Joint at Dissimilar Material
Close
30
(10.50) Vertical Joint at Dissimilar Material
Close
31
(10.51) Vertical Joint at Inside Corner
Close
32
(10.60) Termination at Parapet Cap
Close
33
(10.61) Termination at Feature Parapet
Close
34
(10.62A) Preparation of Roof / Wall Interface
Close
35
(10.62B) Roof / Wall Abutment
Close
36
(10.64) Roofing Termination at Parapet
Close
37
(10.65A) Gold Guard Installation Prior to Saddle Flashing
Close
38
(10.65B) Saddle Flashing Assembly
Close
39
(10.65C) Saddle Flashing at Lower to Higher Wall Abutment
Close
40
(10.70) System Prepared for Penetration
Close
41
(10.75) Scupper Penetration
Close
42
(10.81A) Structural Connection to Substrate (Gold Guard Seal)
Close
43
(10.81B) Structural Connection to Substrate (Barrier Membrane)
Close
44
(10.82) Sign Attachment
Close
45
(20.01) Moisture Protection for CMU
Close
46
(20.02) Air & Moisture Barrier for CMU

All Available 2D CAD Files Back To Top

CAD Drawings Sto Corp. (10.00)  System Components
(10.00) System Components
View CAD
CAD Drawings Sto Corp. (10.10A)  Termination at Grade: Sheathing Flush with Foundation
(10.10A) Termination at Grade:...
View CAD
CAD Drawings Sto Corp. (10.10B)  Termination at Grade: Sheathing overlaps Foundation
(10.10B) Termination at Grade:...
View CAD
CAD Drawings Sto Corp. (10.10C)  Termination at Grade: Concealed Starter Track
(10.10C) Termination at Grade:...
View CAD
CAD Drawings Sto Corp. (10.11)  Termination at Protected Sidewalk
(10.11) Termination at Protected...
View CAD
CAD Drawings Sto Corp. (10.14)  Termination at Grade: Concealed Starter Track
(10.14) Termination at Grade:...
View CAD
CAD Drawings Sto Corp. (10.15)  Termination with Uni-Track Noncombustible Construction
(10.15) Termination with Uni-Track...
View CAD
CAD Drawings Sto Corp. (10.16)  Termination with Uni-Track: Combustible Construction
(10.16) Termination with Uni-Track:...
View CAD
CAD Drawings Sto Corp. (10.23A)  Preparation of Rough Opening
(10.23A) Preparation of Rough Opening
View CAD
CAD Drawings Sto Corp. (10.23B)  Installation of Window Head Flashing
(10.23B) Installation of Window Head...
View CAD
CAD Drawings Sto Corp. (10.23C)  Installation of Sill Flashing Beneath Sill Feature
(10.23C) Installation of Sill Flashing...
View CAD
CAD Drawings Sto Corp. (10.24A)  Commercial Window Head (seal & backer rod)
(10.24A) Commercial Window Head (seal...
View CAD
CAD Drawings Sto Corp. (10.24B)  Commercial Window Head (fillet seal)
(10.24B) Commercial Window Head...
View CAD
CAD Drawings Sto Corp. (10.25A)  Commercial Window Jamb (seal & backer rod)
(10.25A) Commercial Window Jamb (seal...
View CAD
CAD Drawings Sto Corp. (10.25B)  Commercial Window Jamb (fillet seal)
(10.25B) Commercial Window Jamb...
View CAD
CAD Drawings Sto Corp. (10.26A)  Commercial Window Sill (seal & backer rod)
(10.26A) Commercial Window Sill (seal...
View CAD
CAD Drawings Sto Corp. (10.26B)  Commercial Window Sill (fillet seal)
(10.26B) Commercial Window Sill...
View CAD
CAD Drawings Sto Corp. (10.27)  Flanged Window Head
(10.27) Flanged Window Head
View CAD
CAD Drawings Sto Corp. (10.28)  Flanged Window Jamb
(10.28) Flanged Window Jamb
View CAD
CAD Drawings Sto Corp. (10.29)  Flanged Window Sill
(10.29) Flanged Window Sill
View CAD
CAD Drawings Sto Corp. (10.29A)  Flanged Window Sill: Concealed Flashing
(10.29A) Flanged Window Sill:...
View CAD
CAD Drawings Sto Corp. (10.30)  Unvented Insulated Soffit
(10.30) Unvented Insulated Soffit
View CAD
CAD Drawings Sto Corp. (10.31)  Vented Insulated Soffit
(10.31) Vented Insulated Soffit
View CAD
CAD Drawings Sto Corp. (10.33)  Unvented Insulated Soffit (without starter track)
(10.33) Unvented Insulated Soffit...
View CAD
CAD Drawings Sto Corp. (10.40)  Floor Line without Joint
(10.40) Floor Line without Joint
View CAD
CAD Drawings Sto Corp. (10.41)  Floor Line with Joint (Starter Track)
(10.41) Floor Line with Joint (Starter...
View CAD
CAD Drawings Sto Corp. (10.41B)  Floor Line with Joint: Noncombustible Construction
(10.41B) Floor Line with Joint:...
View CAD
CAD Drawings Sto Corp. (10.41C)  Floor Line with Joint: Nocombustible Construction
(10.41C) Floor Line with Joint:...
View CAD
CAD Drawings Sto Corp. (10.42)  Horizontal Joint at Dissimilar Material
(10.42) Horizontal Joint at Dissimilar...
View CAD
CAD Drawings Sto Corp. (10.50)  Vertical Joint at Dissimilar Material
(10.50) Vertical Joint at Dissimilar...
View CAD
CAD Drawings Sto Corp. (10.51)  Vertical Joint at Inside Corner
(10.51) Vertical Joint at Inside Corner
View CAD
CAD Drawings Sto Corp. (10.60)  Termination at Parapet Cap
(10.60) Termination at Parapet Cap
View CAD
CAD Drawings Sto Corp. (10.61)  Termination at Feature Parapet
(10.61) Termination at Feature Parapet
View CAD
CAD Drawings Sto Corp. (10.62A)  Preparation of Roof / Wall Interface
(10.62A) Preparation of Roof / Wall...
View CAD
CAD Drawings Sto Corp. (10.62B)  Roof / Wall Abutment
(10.62B) Roof / Wall Abutment
View CAD
CAD Drawings Sto Corp. (10.64)  Roofing Termination at Parapet
(10.64) Roofing Termination at Parapet
View CAD
CAD Drawings Sto Corp. (10.65A)  Gold Guard Installation Prior to Saddle Flashing
(10.65A) Gold Guard Installation Prior...
View CAD
CAD Drawings Sto Corp. (10.65B)  Saddle Flashing Assembly
(10.65B) Saddle Flashing Assembly
View CAD
CAD Drawings Sto Corp. (10.65C)  Saddle Flashing at Lower to Higher Wall Abutment
(10.65C) Saddle Flashing at Lower to...
View CAD
CAD Drawings Sto Corp. (10.70)  System Prepared for Penetration
(10.70) System Prepared for Penetration
View CAD
CAD Drawings Sto Corp. (10.75)  Scupper Penetration
(10.75) Scupper Penetration
View CAD
CAD Drawings Sto Corp. (10.81A)  Structural Connection to Substrate (Gold Guard Seal)
(10.81A) Structural Connection to...
View CAD
CAD Drawings Sto Corp. (10.81B)  Structural Connection to Substrate (Barrier Membrane)
(10.81B) Structural Connection to...
View CAD
CAD Drawings Sto Corp. (10.82)  Sign Attachment
(10.82) Sign Attachment
View CAD
CAD Drawings Sto Corp. (20.01)  Moisture Protection for CMU
(20.01) Moisture Protection for CMU
View CAD
CAD Drawings Sto Corp. (20.02)  Air & Moisture Barrier for CMU
(20.02) Air & Moisture Barrier for CMU
View CAD