Hunter Industries

MP Rotator Efficiency Goes Unmatched in Usage Test
Portland, OR, USA

Project Details

Location
Portland, OR, USA
Project Year
2008
Size
800 sq ft irrigated

Figuring out a way to produce lush landscapes while using the least amount of water is Hunter Industries' core goal when designing products.
The Water Pollution Control Lab had an irrigation system comprised of over 30 zones, which all utilized traditional spray nozzles. For test purposes, one zone was chosen to be retrofitted with MP Rotator nozzles. The test was set to compare the uniformity and water usage of both types of nozzles.

THE CHALLENGE
The existing system, equipped with traditional spray nozzles was audited for uniformity and precipitation rate using catch cans that were spaced evenly throughout the area of the zone. The nozzles were then replaced with High Efficiency MP Rotator nozzles and the zone was re-audited.

Irrigation Water Audit

THE SOLUTION
The precipitation rate of traditional spray nozzles was 2.84 in/hr, well above the normal soil absorption rate of .5 in/hr, which can lead to flooding conditions and runoff. The MP Rotator's precipitation rate of .55 was much closer to the soil absorption rate reducing runoff and misting conditions.

MP Rotator High Efficiency Spray Nozzle

THE RESULT
The traditional nozzles provided a lower quarter distribution uniformity of 53% while the MP Rotator's lower quarter distribution uniformity was much higher at 71%. The increased performance of the MP Rotator resulted in immediate water saving of 34%. Based on a 35-week watering year, using MP Rotators would result in an annual water savings of 4,185 gallons for the one zone alone.